Follow
Encarnacion Lorenzo
Encarnacion Lorenzo
Grupo sensores químicos y biosensores, Catedrática Química Analítica, UAM
Verified email at uam.es - Homepage
Title
Cited by
Cited by
Year
Determination of organophosphorus and carbamate pesticides using a piezoelectric biosensor
JM Abad, F Pariente, L Hernandez, HD Abruna, E Lorenzo
Analytical Chemistry 70 (14), 2848-2855, 1998
2381998
Aldehyde biosensor based on the determination of NADH enzymically generated by aldehyde dehydrogenase
F Pariente, E Lorenzo, F Tobalina, HD Abruna
Analytical Chemistry 67 (21), 3936-3944, 1995
2251995
Differentiation between graphene oxide and reduced graphene by electrochemical impedance spectroscopy (EIS)
E Casero, AM Parra-Alfambra, MD Petit-Domínguez, F Pariente, ...
Electrochemistry Communications 20, 63-66, 2012
2192012
Mechanistic studies of the electrocatalytic oxidation of NADH and ascorbate at glassy carbon electrodes modified with electrodeposited films derived from 3, 4-dihydroxybenzaldehyde
F Pariente, F Tobalina, G Moreno, L Hernandez, E Lorenzo, HD Abruna
Analytical chemistry 69 (19), 4065-4075, 1997
1771997
Antimonene: a novel 2D nanomaterial for supercapacitor applications
E Martínez‐Periñán, MP Down, C Gibaja, E Lorenzo, F Zamora, CE Banks
Advanced Energy Materials 8 (11), 1702606, 2018
1762018
Electrocatalysis of NADH oxidation with electropolymerized films of 3, 4-dihydroxybenzaldehyde
F Pariente, E Lorenzo, HD Abruna
Analytical Chemistry 66 (23), 4337-4344, 1994
1681994
Design and characterization of a lactate biosensor based on immobilized lactate oxidase onto gold surfaces
A Parra, E Casero, L Vázquez, F Pariente, E Lorenzo
Analytica Chimica Acta 555 (2), 308-315, 2006
1592006
Electrocatalytic oxidation of NADH at glassy carbon electrodes modified with transition metal complexes containing 1, 10-phenanthroline-5, 6-dione ligands
Q Wu, M Maskus, F Pariente, F Tobalina, VM Fernandez, E Lorenzo, ...
Analytical Chemistry 68 (20), 3688-3696, 1996
1551996
Dithiobissuccinimidyl Propionate as an Anchor for Assembling Peroxidases at Electrodes Surfaces and Its Application in a H2O2 Biosensor
M Darder, K Takada, F Pariente, E Lorenzo, HD Abruna
Analytical chemistry 71 (24), 5530-5537, 1999
1411999
Electrodeposition of redox-active films of dihydroxybenzaldehydes and related analogs and their electrocatalytic activity toward NADH oxidation
F Pariente, F TObalina, M Darder, E Lorenzo, HD Abruna
Analytical Chemistry 68 (18), 3135-3142, 1996
1411996
Amperometric flow-through biosensor for the determination of pesticides
C La Rosa, F Pariente, L Hernandez, E Lorenzo
Analytica Chimica Acta 308 (1-3), 129-136, 1995
1381995
Determination of organophosphorus and carbamic pesticides with an acetylcholinesterase amperometric biosensor using 4-aminophenyl acetate as substrate
C La Rosa, F Pariente, L Hernandez, E Lorenzo
Analytica Chimica Acta 295 (3), 273-282, 1994
1121994
Electrochemical sensor for sulfite determination based on iron hexacyanoferrate film modified electrodes
T García, E Casero, E Lorenzo, F Pariente
Sensors and Actuators B: Chemical 106 (2), 803-809, 2005
1082005
Nanostructured rough gold electrodes for the development of lactate oxidase-based biosensors
M Gamero, F Pariente, E Lorenzo, C Alonso
Biosensors and Bioelectronics 25 (9), 2038-2044, 2010
992010
Metallacarboranes on the Road to Anticancer Therapies: Cellular Uptake, DNA Interaction, and Biological Evaluation of Cobaltabisdicarbollide [COSAN]
I Fuentes, T García‐Mendiola, S Sato, M Pita, H Nakamura, E Lorenzo, ...
Chemistry–A European Journal 24 (65), 17239-17254, 2018
972018
Synthesis and electrocatalytic activity towards oxidation of hydrazine of a new family of hydroquinone salophen derivatives: application to the construction of hydrazine sensors
M Revenga-Parra, E Lorenzo, F Pariente
Sensors and Actuators B: Chemical 107 (2), 678-687, 2005
962005
Electrocatalytic oxidation of methanol and other short chain aliphatic alcohols on glassy carbon electrodes modified with conductive films derived from NiII-(N, N′-bis (2, 5 …
M Revenga-Parra, T García, E Lorenzo, F Pariente
Sensors and Actuators B: Chemical 130 (2), 730-738, 2008
932008
Carbon nanodots based biosensors for gene mutation detection
T García-Mendiola, I Bravo, JM López-Moreno, F Pariente, ...
Sensors and Actuators B: Chemical 256, 226-233, 2018
922018
Analytical strategies for amperometric biosensors based on chemically modified electrodes
E Lorenzo, F Pariente, L Hernandez, F Tobalina, M Darder, Q Wu, ...
Biosensors and Bioelectronics 13 (3-4), 319-332, 1998
901998
DNA Biosensor for Detection of Helicobacter pylori Using Phen-dione as the Electrochemically Active Ligand in Osmium Complexes
MV Del Pozo, C Alonso, F Pariente, E Lorenzo
Analytical chemistry 77 (8), 2550-2557, 2005
822005
The system can't perform the operation now. Try again later.
Articles 1–20