The ACE1 electrical impedance tomography system for thoracic imaging MM Mellenthin, JL Mueller, EDLB de Camargo, FS de Moura, TBR Santos, ... IEEE Transactions on Instrumentation and Measurement 68 (9), 3137-3150, 2018 | 67 | 2018 |
A real-time D-bar algorithm for 2-D electrical impedance tomography data M Dodd, JL Mueller Inverse problems and imaging (Springfield, Mo.) 8 (4), 1013, 2014 | 55 | 2014 |
A D-bar algorithm with a priori information for 2-dimensional electrical impedance tomography M Alsaker, JL Mueller SIAM Journal on Imaging Sciences 9 (4), 1619-1654, 2016 | 44 | 2016 |
Incorporating a spatial prior into nonlinear D-bar EIT imaging for complex admittivities SJ Hamilton, JL Mueller, M Alsaker IEEE transactions on medical imaging 36 (2), 457-466, 2016 | 36 | 2016 |
A direct D-bar method for partial boundary data electrical impedance tomography with a priori information M Alsaker, SJ Hamilton, A Hauptmann Inverse Problems and Imaging 11 (3), 427-454, 2017 | 32 | 2017 |
Evaluation of surrogate measures of pulmonary function derived from electrical impedance tomography data in children with cystic fibrosis PA Muller, JL Mueller, M Mellenthin, R Murthy, M Capps, BD Wagner, ... Physiological measurement 39 (4), 045008, 2018 | 31 | 2018 |
Use of an optimized spatial prior in D-bar reconstructions of EIT tank data M Alsaker, JL Mueller Inverse Problems and Imaging 12 (4), 883-901, 2018 | 29 | 2018 |
Estimating regions of air trapping from electrical impedance tomography data JL Mueller, P Muller, M Mellenthin, R Murthy, M Capps, M Alsaker, ... Physiological measurement 39 (5), 05NT01, 2018 | 27 | 2018 |
Dynamic optimized priors for D-bar reconstructions of human ventilation using electrical impedance tomography M Alsaker, JL Mueller, R Murthy Journal of computational and applied mathematics 362, 276-294, 2019 | 17 | 2019 |
Complementary use of priors for pulmonary imaging with electrical impedance and ultrasound computed tomography M Alsaker, DAC Cárdenas, SS Furuie, JL Mueller Journal of computational and applied mathematics 395, 113591, 2021 | 10 | 2021 |
EIT Images of Human Inspiration and Expiration using a D-bar Method with Spatial Priors. M Alsaker, JL Mueller Applied Computational Electromagnetics Society Journal 34 (2), 2019 | 8 | 2019 |
Computational advancements in the D-bar reconstruction method for 2-D electrical impedance tomography M Alsaker Colorado State University. Libraries, 2016 | 7 | 2016 |
A d-bar algorithm with a priori information for electrical impedance tomography M Alsaker, JL Mueller arXiv preprint arXiv:1505.01196, 2015 | 4 | 2015 |
A multithreaded real-time solution for 2D EIT reconstruction with the D-bar algorithm M Alsaker, JL Mueller, A Stahel Journal of Computational Science 67, 101967, 2023 | 1 | 2023 |
Automated filtering in the nonlinear Fourier domain of systematic artifacts in 2D electrical impedance tomography M Alsaker, B Bladow, SE Campbell, EM Kar Inverse Problems and Imaging 16 (3), 647-671, 2022 | 1 | 2022 |
Spatial priors in the D-bar method for human thoracic electrical impedance tomography data M Alsaker, JL Mueller 2018 International Applied Computational Electromagnetics Society Symposium …, 2018 | | 2018 |
Surrogate Measures Of Pulmonary Function Computed From Functional Electrical Impedance Tomography In Children With Cystic Fibrosis JE Hoppe, PA Muller, JL Mueller, MM Mellenthin, R Murthy, M Capps, ... C67. SUPPURATIVE LUNG DISEASES IN CHILDREN, A7673-A7673, 2017 | | 2017 |
C67 SUPPURATIVE LUNG DISEASES IN CHILDREN: Surrogate Measures Of Pulmonary Function Computed From Functional Electrical Impedance Tomography In Children With Cystic Fibrosis JE Hoppe, PA Muller, JL Mueller, MM Mellenthin, R Murthy, M Capps, ... American Journal of Respiratory and Critical Care Medicine 195, 2017 | | 2017 |