A novel electrochemical sensor based on metal-organic framework for electro-catalytic oxidation of L-cysteine H Hosseini, H Ahmar, A Dehghani, A Bagheri, A Tadjarodi, AR Fakhari Biosensors and Bioelectronics 42, 426-429, 2013 | 289 | 2013 |
Au-SH-SiO2 nanoparticles supported on metal-organic framework (Au-SH-SiO2@ Cu-MOF) as a sensor for electrocatalytic oxidation and determination of hydrazine H Hosseini, H Ahmar, A Dehghani, A Bagheri, AR Fakhari, MM Amini Electrochimica Acta 88, 301-309, 2013 | 212 | 2013 |
A new method for the enhancement of electromembrane extraction efficiency using carbon nanotube reinforced hollow fiber for the determination of acidic drugs in spiked plasma … KS Hasheminasab, AR Fakhari, A Shahsavani, H Ahmar Journal of Chromatography A 1285, 1-6, 2013 | 126 | 2013 |
A novel biosensor for liquid phase determination of glutathione and amoxicillin in biological and pharmaceutical samples using a ZnO/CNTs nanocomposite/catechol derivative … H Karimi-Maleh, F Tahernejad-Javazmi, VK Gupta, H Ahmar, MH Asadi Journal of Molecular Liquids 196, 258-263, 2014 | 117 | 2014 |
A sensitive nanocomposite-based electrochemical sensor for voltammetric simultaneous determination of isoproterenol, acetaminophen and tryptophan H Karimi-Maleh, M Moazampour, H Ahmar, H Beitollahi, AA Ensafi Measurement 51, 91-99, 2014 | 116 | 2014 |
Theoretical studies and spectroscopic characterization of novel 4-methyl-5-((5-phenyl-1, 3, 4-oxadiazol-2-yl) thio) benzene-1, 2-diol SS Amiri, S Makarem, H Ahmar, S Ashenagar Journal of Molecular Structure 1119, 18-24, 2016 | 85 | 2016 |
Development of a new pH assisted homogeneous liquid-liquid microextraction by a solvent with switchable hydrophilicity: Application for GC-MS determination of methamphetamine SK Shahvandi, MH Banitaba, H Ahmar Talanta 184, 103-108, 2018 | 81 | 2018 |
A new platform for sensing urinary morphine based on carrier assisted electromembrane extraction followed by adsorptive stripping voltammetric detection on screen-printed electrode H Ahmar, H Tabani, MH Koruni, SSH Davarani, AR Fakhari Biosensors and Bioelectronics 54, 189-194, 2014 | 64 | 2014 |
Electrocatalytic oxidation of hydrazine at glassy carbon electrode modified with ethylenediamine cellulose immobilized palladium nanoparticles H Ahmar, S Keshipour, H Hosseini, AR Fakhari, A Shaabani, A Bagheri Journal of Electroanalytical Chemistry 690, 96-103, 2013 | 64 | 2013 |
Switchable‐hydrophilicity solvent‐based microextraction combined with gas chromatography for the determination of nitroaromatic compounds in water samples J Rameshgar, KS Hasheminasab, L Adlnasab, H Ahmar Journal of separation science 40 (15), 3114-3119, 2017 | 60 | 2017 |
Switchable hydrophilicity solvent-based homogenous liquid–liquid microextraction (SHS-HLLME) combined with GC-FID for the quantification of methadone and tramadol H Ahmar, M Nejati-Yazdinejad, M Najafi, KS Hasheminasab Chromatographia 81, 1063-1070, 2018 | 52 | 2018 |
Electrosynthesis of an imidazole derivative and its application as a bifunctional electrocatalyst for simultaneous determination of ascorbic acid, adrenaline, acetaminophen … N Nasirizadeh, Z Shekari, HR Zare, MR Shishehbore, AR Fakhari, ... Biosensors and Bioelectronics 41, 608-614, 2013 | 52 | 2013 |
Optimization of electromembrane extraction combined with differential pulse voltammetry using modified screen-printed electrode for the determination of sufentanil H Ahmar, AR Fakhari, H Tabani, A Shahsavani Electrochimica Acta 96, 117-123, 2013 | 51 | 2013 |
Application of a new fiber coating based on electrochemically reduced graphene oxide for the cold‐fiber headspace solid‐phase microextraction of tricyclic antidepressants MH Banitaba, SSH Davarani, H Ahmar, SK Movahed Journal of separation science 37 (9-10), 1162-1169, 2014 | 49 | 2014 |
Electrochemical determination of nitrazepam by switchable solvent based liquid-liquid microextraction combined with differential pulse voltammetry S Shahraki, H Ahmar, M Nejati-Yazdinejad Microchemical Journal 142, 229-235, 2018 | 47 | 2018 |
Retraction: Novel 8, 9-dihydroxy-7-methyl-12 H-benzothiazolo [2, 3-b] quinazolin-12-one multiwalled carbon nanotubes paste electrode for simultaneous determination of ascorbic … M Asnaashariisfahani, H Karimi-maleh, H Ahmar, AA Ensafi, AR Fakhari, ... Analytical Methods, 2024 | 44 | 2024 |
Electrocatalytic oxidation of oxalic acid on palladium nanoparticles encapsulated on polyamidoamine dendrimer-grafted multi-walled carbon nanotubes hybrid material H Ahmar, AR Fakhari, MR Nabid, SJT Rezaei, Y Bide Sensors and Actuators B: Chemical 171, 611-618, 2012 | 44 | 2012 |
Fabrication of novel redox-active poly (4, 5-dihydro-1, 3-thiazol-2-ylsulfanyl-3-methyl-1, 2-benzenediol)-gold nanoparticles film on MWCNTs modified electrode: application as … AR Fakhari, H Ahmar, H Hosseini, SK Movahed Sensors and Actuators B: Chemical 213, 82-91, 2015 | 40 | 2015 |
A novel platform sensing based on combination of electromembrane-assisted solid phase microextraction with linear sweep voltammetry for the determination of tramadol AR Fakhari, A Sahragard, H Ahmar, H Tabani Journal of Electroanalytical Chemistry 747, 12-19, 2015 | 39 | 2015 |
Electrochemical determination of dextromethorphan on reduced graphene oxide modified screen‐printed electrode after electromembrane extraction AR Fakhari, MH Koruni, H Ahmar, A Shahsavani, SK Movahed Electroanalysis 26 (3), 521-529, 2014 | 37 | 2014 |